emsl_web_logo

1-800-220-3675

TESTING LABORATORY
ASBESTOS
 
LEAD
SILICA
MOLD
MICROBIOLOGY
INDUSTRIAL HYGIENE
INDOOR AIR QUALITY
ENVIRONMENTAL CHEMISTRY
MATERIALS
MICROSCOPY
MECHANICAL

 EMSL
 Lab Services
 Qualifications
 Chain of Custody
 Locations
 Get Directions
 Contact Us
 Employment
 Photos
 Instrumentation
 Project Exp
 Publications
 Links
 Directory
 Sampling Supplies
 Sampling Guides
 News Articles
 Request Info
 Press / Events
 Forms
 Extranet

Send your questions or comments about this web site to Webmaster@emsl.com

Copyright© 1996-2003 EMSL Analytical, Inc. All rights reserved.

 Mold - Fungi (Air-O-Cell and Tape Lift)

MOLD SEMINARS - REGISTER NOW!
 

AIR-O-CELL SAMPLING

The Air-O-CellTM Air Sampling cassette is a sampling device designed for the rapid collection and analysis of a wide range of airborne aerosols.  These include fungal spores, pollen, insect parts, skin cell fragments, fibers, and inorganic particulates.  Air enters the cassette, the particles become impacted on the sampling substrate, and the air leaves through the exit orifice.  The airflow and patented cassette housing is designed in such a way that the particles are distributed and deposited equally on a special glass slide contained in the cassette housing called the ``trace."

BENEFITS

  • Useful for initial site testing, especially if fungal growth is not visible.
  • Quick and simple procedure.
  • Fast turn around times available.
  • Low chance of sample contamination.

DISADVANTAGES

  • Fungi cannot be fully speciated with this method.  For example, Aspergillus sp. and Penicillium sp. are normally reported together due to the similarities in spore morphology.
  • Spore viability cannot be assessed.

MATERIALS

  • Air-O-CellTM cassette
  • Vacuum pump suitable for operating at 15 liters per minute (lpm)
  • Rotameter (for calibration of vacuum pump)
  • Flexible tubing

Recommended Sampling Procedure

The cassette is designed to operate at a recommended flow rate of 15 lpm.  Lower flow rates may result in a loss of some spores and the accumulation of others in a non-uniform manner.  Higher flow rates may damage the spores. Therefore, it is important not to run the sampling pumps at lower flow rates for longer times to achieve the recommended air volume.

Calibration of Sampling Flow Rate

A specially designed bubble tube, available from the manufacturer, can be used to set the flow rate for the ˝" Air-O-Cell mini pump.  It can not be used with any other style of pump or Mini pump and any other type of sampling pump.

SAMPLING DURATION

The sampling time is dependent on the density of particulate in the environment.  It is important not to overload the sample, otherwise it will be impossible to assess the types of spores, pollen and particulates that are present.  The following table represents typical sample times to attain a sharply defined trace with good dispersion of the spores:

 

Recommended Sampling Intervals for the Air-O-CellTM Air Sampling Cassette at Typical Collection Flow Rates

Typical Environmental Conditions                                              Flow Rates Collection at 15 lpm
Clean ``office" or outdoors (no visible dust)                                  10 minutes
Indoor environment, high activity & personnel                              5 minutes
Indoor environment, drywall renovation or heavy industrial dust     1 minute

SAMPLING PROCEDURE

    1.Prior to sampling, calibrate the pump to 15 liters per minute.

    2.Remove and retain tape seal covering Air-O-CellTM inlet and outlet.

    3.Attach the outlet (round hole) to the supplied tubing adapter (available upon request), or use standard ˝" PVC tubing (for use with high volume pumps only).

    4.Start the sampling pump, and sample for an appropriate period of time (see chart above).

    5.Remove Air-O-CellTM from tubing, and reseal with the original tape.  Label sample.

    6.Complete an EMSL Chain of Custody (COC), available on the website (www.emsl.com), detailing client name and information, project name or number, sample #, description of area, and volume of air used.

    7.To reduce shipping damage, it is recommended that the Air-O-CellTM be placed in a corrugated box to ensure safe arrival at the laboratory.

Quality Control Suggestions

  • An effective interpretation is based on the comparison of indoor and outdoor samples.  An outdoor sample will help demonstrate whether spore amplification is occurring indoors.
  • Obtain a control sample from a non-complaint area for comparison.
  • Sending a blank cassette for analysis periodically is a good practice.
  • Flow rate is critical for accurate results. Remember to calibrate and recalibrate the pump prior to all sampling.  (15 liters/minute)
  • Never use cassettes that are damaged or expired.

For more information contact Zefon International at www.zefon.com

Air-O-CellTM is a registered trademark of Zefon International, 2860 23rd Ave North, St Petersburg, FL 33713.

 


TAPE LIFT SAMPLING


Tape lift, bulk and swab sampling, are techniques used for direct examination.  A direct exam allows for the immediate determination of the presence of fungal spores as well as what types of fungi are present.  Direct examinations should only be used to sample visible mold growth in a contaminated area since most.  Most surfaces collect a mixture of fungal spores that are normally present in the environment.

BENEFITS

  • The direct exam is inexpensive, and can be performed quickly.
  • A useful test for initial site sampling.
  • Direct examination of a surface indicates all mold present in a given area.
  • Direct sampling may reveal indoor reservoirs of spores that have not yet become airborne.

MATERIALS

For Tape lift:

  • Clear (transparent) Scotch or other brand tape (frosted tape hides the spores)
  • New plastic bag to hold specimen(s) (provided in a tape lift kit available from EMSL).

For bulk:

  • Sterile container or new plastic bag or Whirl-a Pack (provided at your request by EMSL) to hold and transport specimen.

For swab:

  • Sterile culturette/swab with appropriate buffer solution to collect and transport specimen (provided at your request by EMSL).

For all matrices:

  • Latex/nitrile gloves (also can be provided at your request).

SAMPLING PROCEDURES

Tapelift:

    1.Take a few inches of clear tape.  Avoid touching the sticky side, especially the part touching the mold.

    2.Wearing gloves, apply the central inch of tape to the suspect area (choose one that is free of extraneous debris).  Apply light pressure to the non-adhesive side.

    3.Pull tape off surface with slow, steady pressure, holding the tape edges only.

    4.Apply sticky side of tape to the inside of the plastic bag.

    5.Ensure there are no folds or creases in the tape.

    6.Close bag

    7.Put only one sample in each bag.

Bulk:

    1.Wearing latex gloves, take a small piece of the suspect material.

    2.Place piece inside clean sterile container or new plastic bag or whirl-a-pack bag.

    3.Close bag or cap container.

Swab:

    1.Wearing gloves, remove swab from packaging material.

    2.Remove plug from media tube.

    3.Swab the desired area thoroughly, rolling the swab lightly back and forth over sampling area.

    4.Insert the swab in the tube, and firmly close cap. 

For all matrices:

    1.Label each sample with appropriate information.

    2.Complete an EMSL Chain of Custody (COC), available on the website (www.emsl.com), detailing client name and information, project name or number, sample #, and a description of the area.

DISADVANTAGES

  • Areas of fungal growth are often small and scattered, so they may not be picked upon sampling.
  • Health problems related to indoor microbial growth are generally caused by the inhalation of substantial numbers of airborne spores, sometimes over a long period of time.  The presence of biological materials on a particular surface, is not a direct indication of what may be in the air.
  • Not all the spores seen under the microscope may be viable (alive).  It is advisable to combine direct exam samples with culture methods to get a better picture of what molds are present.
  • Tape lifts are not able to be cultured.
  • If a direct examination of a swab sample is taken, there is no follow up culture.
  • Direct examinations of dirt/soil and dust samples can not be performed

QUALITY CONTROL SUGGESTIONS

For tapelift:

  • Use clear tape, not frosted.
  • Do not fold tape onto itself.
  • Stick tape on the inside of the plastic bag only.
  • Please do not send tape lift samples on slides or coverslips.  They may arrive broken making the sample difficult to analyze.

For bulks:

  • Send a representative sample of the specimen if large.  This prevents over-handling of the specimen and possible contamination.  If analysis of a specific portion of sample is required, please note area(s) or take a tape lift of area.

For swab:

  • For semi-quantitative sampling, the area swabbed needs to be entered on the chain of custody.

For all matrices

Apply tape, apply swab, or take a small piece of material ONLY from areas where visible mold is seen.